Title:
Clinical Reliability of a Device for Measuring Forces and Moments in Amputee Gait
Clinical Reliability of a Device for Measuring Forces and Moments in Amputee Gait
dc.contributor.author | LeGare, Stephanie | |
dc.contributor.corporatename | School of Applied Physiology | |
dc.contributor.corporatename | College of Sciences | |
dc.contributor.corporatename | College of Sciences | |
dc.contributor.corporatename | School of Biological Sciences | |
dc.date.accessioned | 2009-06-25T17:43:31Z | |
dc.date.available | 2009-06-25T17:43:31Z | |
dc.date.issued | 2009-04-08 | |
dc.description | MSPO Research Presentation, April 8, 2009 at the Centennial Research Building (CRB) Room 119J on the Georgia Tech campus. | en |
dc.description.abstract | Practitioners find it difficult to measure forces and moments on a prosthesis when an amputee walks. Traditional measures, such as using force platforms, are expensive and inaccessible. Practitioners also question the applicability of lab measurements to everyday activities. The iPecs is a portable device that measures forces and moments on a prosthesis. The device demonstrates reliable data over multiple gait speeds and over two testing days (r > 0.9). The iPecs captures characteristic gait data similar to a force platform; however, variations occur due to different coordinate reference planes and the stiffness of the prosthetic foot. Compared to a force platform, iPecs captures more data in less time and fewer overall steps. Portability of the iPecs allows use in daily activities, outdoors, or in clinic, making it an alternative to traditional methods of measuring kinetic data. | en |
dc.format.extent | 20:53 minutes | |
dc.identifier.uri | http://hdl.handle.net/1853/28681 | |
dc.language.iso | en_US | en |
dc.publisher | Georgia Institute of Technology | en |
dc.relation.ispartofseries | MSPO Student Presentations ; 2009 | |
dc.subject | Gait analysis | en |
dc.subject | Transtibial | en |
dc.subject | Amputee | en |
dc.subject | Medical device | en |
dc.subject | Forces | en |
dc.subject | Moments | en |
dc.subject | Reliability | en |
dc.title | Clinical Reliability of a Device for Measuring Forces and Moments in Amputee Gait | en |
dc.type | Moving Image | |
dc.type.genre | Masters Project | |
dc.type.genre | Presentation | |
dspace.entity.type | Publication | |
local.contributor.corporatename | College of Sciences | |
local.contributor.corporatename | School of Biological Sciences | |
local.relation.ispartofseries | Master's Projects | |
local.relation.ispartofseries | Prosthetics and Orthotics Graduate Progam | |
relation.isOrgUnitOfPublication | 85042be6-2d68-4e07-b384-e1f908fae48a | |
relation.isOrgUnitOfPublication | c8b3bd08-9989-40d3-afe3-e0ad8d5c72b5 | |
relation.isSeriesOfPublication | 09b1c264-93da-4a60-8e57-4eecff715bc6 | |
relation.isSeriesOfPublication | a5eb8fcf-f60d-47ce-ba10-668ed019b518 |
Files
Original bundle
1 - 3 of 3
No Thumbnail Available
- Name:
- legare.mp4
- Size:
- 32.81 MB
- Format:
- MP4 Video file
- Description:
- Download Video
No Thumbnail Available
- Name:
- legare_videostream.html
- Size:
- 985 B
- Format:
- Hypertext Markup Language
- Description:
- Streaming Video
No Thumbnail Available
- Name:
- Transcription.txt
- Size:
- 14.45 KB
- Format:
- Plain Text
- Description:
- Transcription
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.86 KB
- Format:
- Item-specific license agreed upon to submission
- Description: