Title:
Rolling element skew measurement in a spherical roller bearing utilizing a CPD probe

Thumbnail Image
Author(s)
Osorno, Daniel
Authors
Advisor(s)
Danyluk, Steven
Advisor(s)
Editor(s)
Associated Organization(s)
Series
Supplementary to
Abstract
This thesis incorporates an array of Contact Potential Difference (CPD) sensors to measure and monitor the degree of skew in the rolling elements of a spherical roller bearing. Skewing is the motion of a roller as it turns about an axis normal to the roller race interface. Roller skew is generated as part of the kinematic effects of roller bearings. Skew monitoring is important for bearing design as it is an indirect measure of bearing life. For the purpose of this thesis, roller skew was measured utilizing multiple pairs of CPD probes located around the bearings outer raceway at varying points of the loading zone. These CPD probes are not in direct contact with the rollers, but in close proximity to their surface (through the bearing outer ring). The skew angle measured is related to different operating conditions such as applied load, shaft speed, and lubrication. The pair of CPD probes detected a signal as the roller surface passed by and the phase difference between the two distinct signals measured the skew angles in the range of 0.016 to 1.10. The shaft is rotated both clockwise and counterclockwise to capture any probe misalignment which was in the range of 0.5 up to 2.0 . This thesis also provides a model for the probe signal as a spherical roller surface passes the probe surface.
Sponsor
Date Issued
2005-08-24
Extent
3197789 bytes
Resource Type
Text
Resource Subtype
Thesis
Rights Statement
Rights URI