Person:
Hunt, William D.

Associated Organization(s)
ORCID
ArchiveSpace Name Record

Publication Search Results

Now showing 1 - 1 of 1
  • Item
    In Situ Acoustic Temperature Measurement During Variable-Frequency Microwave Curing
    (Georgia Institute of Technology, 2008-10) Davis, Cleon E. ; Dickherber, Anthony ; Hunt, William D. ; May, Gary S.
    Variable-frequency microwave (VFM) curing can perform the same processing steps as conventional thermal processing in minutes, without compromising intrinsic material properties. With increasing demand for novel dielectrics, there is a corresponding demand for new processing techniques that lead to comparable or better properties than conventional methods. VFM processing can be a viable alternative to conventional thermal techniques. However, current limitations include a lack of reliable temperature measuring techniques. This research focuses on developing a reliable temperature measuring system using acoustic techniques to monitor low-k polymer dielectrics cured on silicon wafers in a VFM furnace. The acoustic sensor exhibits the capability to measure temperatures from 20 degrees C to 300 degrees C with an attainable accuracy of ± 2 degrees.