Title:
Pulsatile Flow System for Surgical Robotics

dc.contributor.author Verma, Ankita
dc.contributor.committeeMember Desai, Jaydev
dc.contributor.department Biomedical Engineering (Joint GT/Emory Department)
dc.contributor.department Biomedical Engineering (Joint GT/Emory Department)
dc.date.accessioned 2020-11-09T16:59:17Z
dc.date.available 2020-11-09T16:59:17Z
dc.date.created 2019-12
dc.date.issued 2019-12
dc.date.submitted December 2019
dc.date.updated 2020-11-09T16:59:17Z
dc.description.abstract Surgical robotics is an evolving field where robotic medical devices are utilized to perform surgery either on or within the body. In order to mitigate errors that may occur during surgery due to the medical devices being used, testing environments are created for better development of the device and for clinical training. A Pulsatile Flow System (PFS) is a machine that recreates the physiological conditions of flow rate and pressure as the heart pumps blood, and can be created using materials such as pipes and motors. The research at hand developed a PFS and specifically focused on the electrical components of the system, using a motor, a motor controller, a flow sensor, and a circuit board. By creating code that is able to control the system and the speed at which the PFS functions, the system was able to pump water at 40 beats per minute through the circuit. Moving forward, the PFS can be improved to become an even more accurate model by including changes such as substituting the water in the system with a liquid of a similar viscosity to blood. The development of a machine like this is crucial in order to provide a cost effective system capable of imitating the human body in order to properly test surgical robots that travel through arteries in the body. Using an external testing environment will ensure that the devices created in the laboratory are properly developed before they are used in surgery, ensuring that the patient’s life is kept out of harm’s way.
dc.description.degree Undergraduate
dc.format.mimetype application/pdf
dc.identifier.uri http://hdl.handle.net/1853/63856
dc.publisher Georgia Institute of Technology
dc.subject Surgical robotics
dc.subject Medical device
dc.subject Biomedical engineering
dc.subject Pulsatile flow system
dc.title Pulsatile Flow System for Surgical Robotics
dc.type Text
dc.type.genre Undergraduate Thesis
dspace.entity.type Publication
local.contributor.corporatename Wallace H. Coulter Department of Biomedical Engineering
local.contributor.corporatename Undergraduate Research Opportunities Program
local.contributor.corporatename College of Engineering
local.relation.ispartofseries Undergraduate Research Option Theses
relation.isOrgUnitOfPublication da59be3c-3d0a-41da-91b9-ebe2ecc83b66
relation.isOrgUnitOfPublication 0db885f5-939b-4de1-807b-f2ec73714200
relation.isOrgUnitOfPublication 7c022d60-21d5-497c-b552-95e489a06569
relation.isSeriesOfPublication e1a827bd-cf25-4b83-ba24-70848b7036ac
thesis.degree.level Undergraduate
Files
Original bundle
Now showing 1 - 1 of 1
Thumbnail Image
Name:
VERMA-UNDERGRADUATERESEARCHOPTIONTHESIS-2019.pdf
Size:
2.84 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
LICENSE.txt
Size:
3.86 KB
Format:
Plain Text
Description: