Title:
End-to-end testing of the Leksell Gamma Knife Icon system

dc.contributor.advisor Wang, C.-K. Chris
dc.contributor.advisor Rahnema, Sara
dc.contributor.author Burton, Krista
dc.contributor.committeeMember Hertel, Nolan
dc.contributor.department Mechanical Engineering
dc.date.accessioned 2018-01-22T21:14:18Z
dc.date.available 2018-01-22T21:14:18Z
dc.date.created 2017-12
dc.date.issued 2017-12-11
dc.date.submitted December 2017
dc.date.updated 2018-01-22T21:14:18Z
dc.description.abstract The Leksell Gamma Knife Icon is a stereotactic radiosurgery system that is used to non-invasively treat brain lesions. It incorporates 192 fixed cobalt-60 sources, which ensures the highest degree of accuracy during treatment due to the minimization of potential error from stationary sources. The gamma knife’s precision and special modifications for conformity to the human brain ensure faster treatments and fractionated options, delivered in a few hours on a single day, as opposed to treatment on consecutive days. A titanium-alloy frame affixed to the skull of a patient before each treatment has defined the stereotactic coordinate system of previous gamma knife models, as well as provided complete patient immobilization during treatment. However, the newest gamma knife model from Elekta, the Icon, introduced a frameless treatment option that utilizes an on-board cone-beam computed tomography (CBCT) imager for patient positioning and a motion tracking system to monitor patient movement during treatment. When using this option, the stereotactic coordinate system is defined by the CT image taken before treatment, and a thermoplastic mask is used for moderate patient immobilization, as opposed to the titanium-alloy frame. Since the opportunities for positioning misalignment and out-of-tolerance patient movement is now introduced to the treatment, thorough research and end-to-end testing was conducted to make sure that correction calculations and monitoring methods are being performed to keep these concerns to a minimum and provide an accurate and precise radiosurgery procedure. This project was conducted to consider extreme patient movement during radiosurgery procedures and provide additional end-to-end testing on the Leksell Gamma Knife system at Emory Saint Joseph’s Hospital in Atlanta, Georgia. The performed testing verified the integrated imaging system by treating a moving target that required position shifts between treatments to mimic patient misalignments, observing the ability of the system to accurately correct patient shifts during setup. Additionally, this work evaluated the motion tracking system by treating a moving target, which mimicked patient chin-like movements during treatment, monitoring the tolerance at which there was a clinical detriment to the quality of the plan due to patient motion.
dc.description.degree M.S.
dc.format.mimetype application/pdf
dc.identifier.uri http://hdl.handle.net/1853/59298
dc.language.iso en_US
dc.publisher Georgia Institute of Technology
dc.subject Gamma knife
dc.subject EBT3
dc.subject Icon
dc.title End-to-end testing of the Leksell Gamma Knife Icon system
dc.type Text
dc.type.genre Thesis
dspace.entity.type Publication
local.contributor.advisor Wang, C.-K. Chris
local.contributor.corporatename George W. Woodruff School of Mechanical Engineering
local.contributor.corporatename College of Engineering
relation.isAdvisorOfPublication 71d23899-d6d4-4d7f-b9bc-d30323a6f442
relation.isOrgUnitOfPublication c01ff908-c25f-439b-bf10-a074ed886bb7
relation.isOrgUnitOfPublication 7c022d60-21d5-497c-b552-95e489a06569
thesis.degree.level Masters
Files
Original bundle
Now showing 1 - 1 of 1
Thumbnail Image
Name:
BURTON-THESIS-2017.pdf
Size:
2.25 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
LICENSE.txt
Size:
3.87 KB
Format:
Plain Text
Description: