Title:
Influence of the Implant Location on the Hinge and Leakage Flow Fields Through Bileaflet Mechanical Heart Valves

dc.contributor.advisor Yoganathan, Ajit P.
dc.contributor.author Simon, Helene A. en_US
dc.contributor.committeeMember Sambanis Athanassios
dc.contributor.committeeMember Sotiropoulos Fotis
dc.contributor.department Chemical Engineering en_US
dc.date.accessioned 2005-03-03T21:53:24Z
dc.date.available 2005-03-03T21:53:24Z
dc.date.issued 2004-04-08 en_US
dc.description.abstract Native heart valves that have limited functionality due to cardiovascular disease or congenital birth defects are commonly replaced by prosthetic heart valves. Bileaflet mechanical heart valves (BMHV) are the most commonly implanted valve design due to their long-term durability. However, their unnatural hemodynamics promote thrombosis and thromboembolic events. Clinical reports and in vitro experiments suggest that the thrombogenic complications in bileaflet valves are related to the stress imposed on blood by the valves during the closing phase. Additionally, animal and clinical studies have shown that BMHV in the aortic position demonstrate reduced failure rates compared to identical valves in the mitral position. The present study aimed to investigate the leakage, hinge, and near hinge flow fields of two BMHV under simulated physiologic aortic flow conditions and to compare these results with previous findings in the mitral position to better understand how the implant location influences the valve performance and the subsequent risk of blood damage. Two and three-component Laser Doppler Velocimetry techniques were used to quantify the velocity and turbulent shear stress fields in both the hinge and the upstream leakage flow regions. The study focused on the 23 mm St. Jude Medical Regent (SJM) and the 23 mm CarboMedics (CM) valves. Although they were tested under similar physiologic conditions, shape and location of the leakage jets were dependent on valve design. Nevertheless, turbulent shear stress levels recorded within all jets were well above the threshold shear stress for the onset of blood cell damage. Within the hinge region, the flow fields were complex and unsteady. The angulated hinge recess of the CM valve appeared to promote blood damage while the streamlined geometry of the SJM valve contributed to better washout of the hinge region. Animations of the velocity flow fields are given in QuickTime or MPEG format. Comparison of the present findings with previously published results for the mitral position suggests that the superior clinical results of the mechanical valves in the aortic position may be due to less severe leakage flow upon valve closure as well as to enhanced hinge washout during the forward flow phase. en_US
dc.description.degree M.S. en_US
dc.format.extent 522331 bytes
dc.format.extent 617659 bytes
dc.format.extent 615868 bytes
dc.format.extent 602588 bytes
dc.format.extent 457750 bytes
dc.format.extent 578272 bytes
dc.format.extent 535487 bytes
dc.format.extent 534205 bytes
dc.format.extent 419646 bytes
dc.format.extent 611619 bytes
dc.format.extent 925834 bytes
dc.format.extent 1009631 bytes
dc.format.extent 976930 bytes
dc.format.extent 780180 bytes
dc.format.extent 9091193 bytes
dc.format.mimetype video/quicktime
dc.format.mimetype video/quicktime
dc.format.mimetype video/quicktime
dc.format.mimetype video/quicktime
dc.format.mimetype video/quicktime
dc.format.mimetype video/quicktime
dc.format.mimetype video/quicktime
dc.format.mimetype video/quicktime
dc.format.mimetype video/quicktime
dc.format.mimetype video/quicktime
dc.format.mimetype video/mpeg
dc.format.mimetype video/quicktime
dc.format.mimetype video/mpeg
dc.format.mimetype video/quicktime
dc.format.mimetype application/pdf
dc.identifier.uri http://hdl.handle.net/1853/5159
dc.language.iso en_US
dc.publisher Georgia Institute of Technology en_US
dc.subject Laser Doppler velocimetry en_US
dc.subject Thrombosis
dc.subject Hinge
dc.subject Implant location
dc.subject CarboMedics valve
dc.subject St. Jude Medical Regent valve
dc.subject Leakage jets
dc.title Influence of the Implant Location on the Hinge and Leakage Flow Fields Through Bileaflet Mechanical Heart Valves en_US
dc.type Text
dc.type.genre Thesis
dspace.entity.type Publication
local.contributor.advisor Yoganathan, Ajit P.
local.contributor.corporatename School of Chemical and Biomolecular Engineering
local.contributor.corporatename College of Engineering
relation.isAdvisorOfPublication 6a910742-4bed-4ba6-b03d-f92e4c915a00
relation.isOrgUnitOfPublication 6cfa2dc6-c5bf-4f6b-99a2-57105d8f7a6f
relation.isOrgUnitOfPublication 7c022d60-21d5-497c-b552-95e489a06569
Files
Original bundle
Now showing 1 - 5 of 15
No Thumbnail Available
Name:
simon_helene_a_200405_mast_hinge_cm_flatlevel.mov
Size:
510.09 KB
Format:
Video Quicktime
Description:
No Thumbnail Available
Name:
simon_helene_a_200405_mast_hinge_sjm_500micronslevel.mov
Size:
603.18 KB
Format:
Video Quicktime
Description:
No Thumbnail Available
Name:
simon_helene_a_200405_mast_hinge_sjm_1mmlevel.mov
Size:
601.43 KB
Format:
Video Quicktime
Description:
No Thumbnail Available
Name:
simon_helene_a_200405_mast_hinge_sjm_3mmlevel.mov
Size:
588.46 KB
Format:
Video Quicktime
Description:
No Thumbnail Available
Name:
simon_helene_a_200405_mast_hinge_sjm_195micronslevel.mov
Size:
447.02 KB
Format:
Video Quicktime
Description: