Title:
Long-term patency of a polymer vein valve

dc.contributor.advisor Ku, David N.
dc.contributor.author Midha, Prem Anand en_US
dc.contributor.committeeMember Gleason, Rudolph
dc.contributor.committeeMember Milner, Ross
dc.contributor.department Bioengineering en_US
dc.date.accessioned 2009-08-26T18:13:54Z
dc.date.available 2009-08-26T18:13:54Z
dc.date.issued 2009-07-08 en_US
dc.description.abstract Chronic Venous Insufficiency (CVI) is a condition in present in almost 27% of adults in which an insufficient amount of blood is pumped back to the heart due to damaged or poorly apposed one-way valves in the leg veins. During forward flow, vein valves allow blood to return to the heart while posing very little resistance to the flow. During gravity-driven reverse flow, normal valves close and prevent blood from flowing backward through the valve. Incompetent, or damaged, vein valves cannot prevent this reverse flow and lead to a pooling of blood at the feet. CVI is a painful disease presents itself in various ways, including varicose veins, ulcerations of the lower extremities, and severe swelling. Current therapies and treatments include compressive stockings, destruction or removal of affected veins, valve repair, and valve transplants. The implantation of prosthetic vein valves is a future treatment option that does not require an invasive surgery, human donor, or lengthy hospital stay. While no prosthetic vein valves are currently commercially available, this thesis describes the design, verification, and validation of a novel prosthetic vein valve. Verification tests include CFD simulations, functional tests, mechanical tests, and in vitro thromogenicity tests. The validation of the device was done through an animal study in sheep external jugular veins. CFD analysis verified that shear rates within the valve support its lower thrombogenicity as compared to a previous vein valve. Benchtop tests demonstrate superiority in short-term patency over a previous polymer valve. In a sheep study, patency was shown at 6 weeks, surpassing many autograft valves and showing great potential to meet the goal of 3 month patency in sheep. en_US
dc.description.degree M.S. en_US
dc.identifier.uri http://hdl.handle.net/1853/29721
dc.publisher Georgia Institute of Technology en_US
dc.subject Vein valve en_US
dc.subject Deep vein thrombosis en_US
dc.subject Venous valve en_US
dc.subject Prosthetic vein valve en_US
dc.subject Chronic venous insufficiency en_US
dc.subject.lcsh Venous valves
dc.subject.lcsh Hemodynamics
dc.subject.lcsh Implants, Artificial
dc.subject.lcsh Veins
dc.title Long-term patency of a polymer vein valve en_US
dc.type Text
dc.type.genre Thesis
dspace.entity.type Publication
local.contributor.advisor Ku, David N.
local.contributor.corporatename College of Engineering
local.contributor.corporatename College of Engineering
local.relation.ispartofseries Master of Science in Bioengineering
relation.isAdvisorOfPublication fcccb519-e993-4e74-80be-d919b82c6af4
relation.isOrgUnitOfPublication 7c022d60-21d5-497c-b552-95e489a06569
relation.isOrgUnitOfPublication 7c022d60-21d5-497c-b552-95e489a06569
relation.isSeriesOfPublication a5c9fe8c-5d03-4de6-a761-459fb2af0dea
Files
Original bundle
Now showing 1 - 1 of 1
Thumbnail Image
Name:
midha_prem_a_200905_mast.pdf
Size:
138.07 MB
Format:
Adobe Portable Document Format
Description: