Title:
Sensitivity variation in two-center holographic recording
Sensitivity variation in two-center holographic recording
dc.contributor.author | Momtahan, Omid | en_US |
dc.contributor.author | Cadena, George H. | en_US |
dc.contributor.author | Adibi, Ali | en_US |
dc.contributor.corporatename | Georgia Institute of Technology. Center for Organic Photonics and Electronics | en_US |
dc.contributor.corporatename | Georgia Institute of Technology. School of Electrical and Computer Engineering | en_US |
dc.date.accessioned | 2012-12-03T21:03:10Z | |
dc.date.available | 2012-12-03T21:03:10Z | |
dc.date.issued | 2005-10 | |
dc.description | © 2005 Optical Society of America | en_US |
dc.description | The definitive version of this paper is available at: http://dx.doi.org/10.1364/OL.30.002709 | en_US |
dc.description | DOI: 10.1364/OL.30.002709 | en_US |
dc.description.abstract | An experimental study of variation of sensitivity with recording and sensitizing intensities in two-center recording is presented. The experimental results are in good agreement with the theoretical predictions. It is shown experimentally, for what is to our knowledge the first time, that the sensitivity is a function of the ratio of recording to sensitizing intensities and not the absolute intensities. Also, the ratio of recording to sensitizing intensities should be small to obtain high sensitivity values. We also report the highest sensitivity (S=0.15 cm/J) that has been achieved to date for a LiNbO₃:Fe:Mn crystal | en_US |
dc.identifier.citation | Momtahan, O. and Cadena, George and Adibi, Ali, "Sensitivity variation in two-center holographic recording," Optics Letters, 30, 20, 2709-2711 (October 15 2005) | en_US |
dc.identifier.doi | 10.1364/OL.30.002709 | |
dc.identifier.issn | 0146-9592 | |
dc.identifier.uri | http://hdl.handle.net/1853/45487 | |
dc.language.iso | en_US | en_US |
dc.publisher | Georgia Institute of Technology | en_US |
dc.publisher.original | Optical Society of America | en_US |
dc.subject | Holography | en_US |
dc.subject | Optical storage materials | en_US |
dc.subject | Volume gratings | en_US |
dc.title | Sensitivity variation in two-center holographic recording | en_US |
dc.type | Text | |
dc.type.genre | Article | |
dspace.entity.type | Publication | |
local.contributor.author | Adibi, Ali | |
local.contributor.corporatename | Center for Organic Photonics and Electronics | |
relation.isAuthorOfPublication | 3f390cd1-919c-4946-af63-6f9f1e244776 | |
relation.isOrgUnitOfPublication | 43f8dc5f-0678-4f07-b44a-edbf587c338f |
Files
Original bundle
1 - 1 of 1