Title:
Experimental investigation of hospital operating room air distribution

dc.contributor.advisor Jeter, Sheldon M.
dc.contributor.author Stevenson, Tyler C. en_US
dc.contributor.committeeMember Ghiaasiaan, S. Mostafa
dc.contributor.committeeMember Joshi, Yogena
dc.contributor.department Mechanical Engineering en_US
dc.date.accessioned 2008-06-10T20:38:01Z
dc.date.available 2008-06-10T20:38:01Z
dc.date.issued 2008-01-15 en_US
dc.description.abstract Surgical Site Infections (SSI) are a significant and potentially preventable source of illness and death for surgical patients. An unknown, but potentially significant fraction of SSI may be caused by airborne infectious particles. Improved or optimized room air distribution may reduce these infections by minimizing the transport of infectious particles into the surgical site. A sophisticated CFD analysis, previously conducted by researchers at the National Institutes of Health (NIH), found that a buoyant thermal plume produced by heat from the surgical site itself could play a significant role in protecting the site from infectious particles. This study experimentally determines the airflow patterns around a simulated patient in a mock operating room using particle image velocimetry (PIV) to find the influence of the buoyant thermal plume on the flow. In addition, independent CFD analysis was performed using a standard commercial CFD program both to help guide and interpret the experimental results and to test the performance of a more readily available tool in predicting the experimental findings. The results of the experimental results and CFD analysis were quantitatively compared to find their agreement. en_US
dc.description.degree M.S. en_US
dc.identifier.uri http://hdl.handle.net/1853/22574
dc.publisher Georgia Institute of Technology en_US
dc.subject PIV en_US
dc.subject Buoyant thermal en_US
dc.subject Air flow patterns en_US
dc.subject.lcsh Operating rooms--Environmental engineering
dc.subject.lcsh Air flow
dc.subject.lcsh Computational fluid dynamics
dc.title Experimental investigation of hospital operating room air distribution en_US
dc.type Text
dc.type.genre Thesis
dspace.entity.type Publication
local.contributor.advisor Jeter, Sheldon M.
local.contributor.corporatename George W. Woodruff School of Mechanical Engineering
local.contributor.corporatename College of Engineering
relation.isAdvisorOfPublication 5e27045b-759d-4d83-ab1b-3dd5395dc628
relation.isOrgUnitOfPublication c01ff908-c25f-439b-bf10-a074ed886bb7
relation.isOrgUnitOfPublication 7c022d60-21d5-497c-b552-95e489a06569
Files
Original bundle
Now showing 1 - 1 of 1
Thumbnail Image
Name:
stevenson_tyler_c_200805_mast.pdf
Size:
7.8 MB
Format:
Adobe Portable Document Format
Description: