Title:
Experimental and Numerical Study of Dual-Chamber Thermosyphon

Thumbnail Image
Author(s)
Pal, Aniruddha
Authors
Advisor(s)
Joshi, Yogendra
Advisor(s)
Editor(s)
Associated Organization(s)
Series
Supplementary to
Abstract
An experimental and numerical investigation was conducted to study boiling and condensation - the two most important phenomena occurring in a dual-chamber thermosyphon. Boiling experiments were carried out using water at sub-atmospheric pressures of 9.7, 15 and 21 kPa with a three-dimensional porous boiling enhancement structure integrated in the evaporator. Sub-atmospheric pressure boiling achieved heat fluxes in excess of 100 W/cm2 with negligible incipience superheat, for wall temperatures below 85 oC. Reduced pressures resulted in reduction of heat transfer coefficient with decrease in saturation pressure. The boiling enhancement structure showed considerable heat transfer enhancement compared to boiling from plain surface. Increased height of the structure decreased the heat transfer coefficient and suggested the existence of an optimum structure height for a particular saturation pressure. A parametric study showed that a reduction in liquid level of water increased the CHF for boiling with plain surfaces. For boiling with enhanced structures, the liquid level for optimum heat transfer increased with increasing height of the enhanced structure. A numerical model was developed to study condensation of water in horizontal rectangular microchannels of hydraulic diameters 150-375 µm. The model incorporated surface tension, axial pressure gradient, liquid film curvature, liquid film thermal resistance, gravity and interfacial shear stress, and implemented successive solution of mass, momentum and energy balance equations for both liquid and vapor phases. Rectangular microchannels achieved significantly higher heat transfer coefficient compared to a circular channel of similar hydraulic diameter. Increasing the inlet mass flow rate resulted in a higher heat transfer coefficient. Increasing the inlet temperature difference between wall and vapor led to a thicker film and a gradually decreasing heat transfer coefficient. Increasing the channel dimensions led to higher heat transfer coefficient, with a reduction in the vapor pressure drop along the axial direction of the channel. The unique contributions of the study are: extending the knowledge base and contributing unique results on the thermal performance of thermosyphons, and development of a analytical model of condensation in rectangular microchannels, which identified the system parameters that affects the flow and thermal performance during condensation.
Sponsor
Date Issued
2007-05-18
Extent
Resource Type
Text
Resource Subtype
Dissertation
Rights Statement
Rights URI