Title:
Multi-resolution 3D Nonrigid Registration via Optimal Mass Transport on the GPU
Multi-resolution 3D Nonrigid Registration via Optimal Mass Transport on the GPU
dc.contributor.author | Rehman, Tauseef ur | |
dc.contributor.author | Pryor, Gallagher D. | |
dc.contributor.author | Melonakos, John | |
dc.contributor.author | Tannenbaum, Allen R. | |
dc.contributor.corporatename | Georgia Institute of Technology. College of Computing | |
dc.contributor.corporatename | Georgia Institute of Technology. School of Electrical and Computer Engineering | |
dc.date.accessioned | 2009-07-29T19:22:56Z | |
dc.date.available | 2009-07-29T19:22:56Z | |
dc.date.issued | 2007 | |
dc.description | Presented at MICCAI 2007 Workshop on Computational Biomechanics for Medicine II, Brisbane Australia, 29 October - 2 November 2007. | en |
dc.description.abstract | In this paper we present computationally efficient implementation of the minimizing flow approach for optimal mass transport (OMT) with applications to non-rigid 3D image registration. Our implementation solves the OMT problem via multi-resolution, multigrid, and parallel methodologies on a consumer graphics processing unit (GPU). Although computing the optimal map has shown to be computationally expensive in the past, we show that our approach is almost two orders magnitude faster than previous work and is capable of finding transport maps with optimality measures (mean curl) previously unattainable by other works (which directly influences the accuracy of registration). We give results where the algorithm was used to compute non-rigid registrations of 3D synthetic data as well as intra-patient pre-operative and post-operative 3D brain MRI datasets. | en |
dc.identifier.citation | Tauseef ur Rehman, Gallagher Pryor, John Melonakos, and Allen Tannenbaum, "Multi-resolution 3D Nonrigid Registration via Optimal Mass Transport on the GPU," Proceedings of Computational Biomechanics for Medicine-II, MICCAI, 2007, 122-132 | en |
dc.identifier.uri | http://hdl.handle.net/1853/29321 | |
dc.language.iso | en_US | en |
dc.publisher | Georgia Institute of Technology | en |
dc.subject | Image registration | en |
dc.subject | Optimal mass transport | en |
dc.subject | Medical image processing | en |
dc.subject | Algorithms | en |
dc.subject | Multi-resolution | en |
dc.title | Multi-resolution 3D Nonrigid Registration via Optimal Mass Transport on the GPU | en |
dc.type | Text | |
dc.type.genre | Proceedings | |
dspace.entity.type | Publication | |
local.contributor.corporatename | Wallace H. Coulter Department of Biomedical Engineering | |
local.contributor.corporatename | College of Engineering | |
relation.isOrgUnitOfPublication | da59be3c-3d0a-41da-91b9-ebe2ecc83b66 | |
relation.isOrgUnitOfPublication | 7c022d60-21d5-497c-b552-95e489a06569 |